- 行业新闻
-
北京翻译公司完成水系统自动消毒器简介英文翻译
发布时间:2018-11-01 09:15 点击:
北京翻译公司完成水系统自动消毒器简介英文翻译
Water system self-cleaning sterilizer Installation and operation manualBEIJING YUHUI WATER TREATMENT CO., LTDInstallation sketch溢流口Overflow outlet水箱出水口Tank outlet水箱Tank阀门ValveY式过滤器Y-shape filter预留回水孔Reserved returning hole进水管Inlet pipe水系统自洁消毒器Water system self-cleaning sterilizer人孔Manhole水箱进水口Tank inlet最低液位Lowest fluid level回水管Returning pipe说明:水系统自洁消毒器的回水管在水箱中间。Note:The returning pipe of the water system self-cleaning sterilizer lies at the center of the tank.Foundation and distance to the wall◆Foundation requirements: smooth concrete pavement◆Requirements for distance to the wall: It’s required the distance to the wall is not less than 400mm for the convenience of the equipment maintenance.Wiring requirements:The equipment power supply is of single-phase three-wire of AC220V/50Hz, with a live wire, neural wire and zero wire.Operation state display:The power indicator is lighting when the equipment is powered. The operation indicator and processor indicator are lighting when the equipment is in the operation. When the equipment is standby, the operation indicator is lighting and the processor indicator goes out and the digital voltmeter displays the voltage of DC12V of the equipment. The processor indicator is lighting and the digital voltmeter displays nothing in case of the equipment in fault.Fault◆Breaker tripping and short circuit: please examine whether there is short circuit of the pump or the equipment.◆Abnormal display of digital voltmeter or ampere meter, self-cleaning sterilization processor A in fault: please examine whether there is short circuit of the processor power supply module or the processor cable.Operation descriptions (operation notes)◆Starting: to examine whether the ON/OFF rotary knob on the equipment panel is in OFF position before starting the equipment; to switch on the air switch of the power supply in the cabinet and the equipment is in the state of stopping with the power indicator lighting and operation indicator going out after the equipment is power.◆Operation process: (ON/OFF rotary knob: in the position of ON with the operation indicator lighting)The equipment is in automatic operation, the self-cleaning sterilization processor A switches regularly for the treatment of the system water. The voltmeter or amperemeter are flashing when the processor A is switching, which is normal.◆Operation state display: The voltmeter or amperemeter on the equipment panel display the voltage or current conditions of the self-cleaning sterilization processor A respectively. The voltmeter displays internally DC12V approximately and the DC current value on the amperemeter will be different depending on the changing water quality in the system.◆Equipment fault alarm: The voltmeter of the equipment will display DC12V approximately in normal condition. The abnormal display or the processor indicator going out possibly means the fault of the voltmeter, fault in DC12V power module of the self-cleaning sterilization processor A or short circuit of the processor A.◆Notes in the equipment operation:① The equipment should have the sound ventilation and the voltage fluctuation should be not larger than 10%;② The examination should be made on the operation performance of each component and whether the pipelines are connected correctly before the equipment is put into operation. The equipment should be put into normal operation only passing the examination;③ The equipment must be operated with the system filled with water.Beijing Yuhui Water Treatment Co., Ltd.Add: Printing S&T World Tower No. 2 Cuiwei Road Haidian District BeijingTel:Fax:Postcode:Website:E-mail:世联北京翻译公司,全球品质,服务中国.2006年进入北京市场,超过1万家本土翻译客户,每天近600万字的信息,近千万元的贸易通过世联翻译走向全球.Translation Company China外国语翻译专家! 欧美语言与翻译服务外包供应商! 尖端工业技术和商务领域多语翻译!立即拨打010-64809262免费咨询,专业英语翻译、英汉互译、中译英、中文翻译英文等语言服务,政府和国际组织,跨国公司和大中型企业等北京翻译采购专业供应商!- 上一篇:北京翻译公司完成机械使用信息中文翻译
- 下一篇:北京翻译公司完成CAD关键词英文翻译